Helping to Keep Your Workers Safe with Fall Protection Systems and Equipment

The city of Los Angeles resides in the state of California and California has an approved OSHA State Plan called Cal-OSHA. Regarding fall protection, Cal-OSHA refers to OSHA CFR 2019 for all applicable fall protection requirements.

Along with Cal-OSHA, the city of Los Angeles has their own building code which is known as the California City of Los Angeles Building Code (CACLABC). CACLABC adheres to the International Building Code standards, but applies amendments that are relevant to the city.

Understanding Los Angeles Fall Protection Requirements

OSHA Standard Interpretation - Do I follow OSHA or local building code in Los Angelos?

The strictest rules must be followed. Where local codes are in effect, they are generally more specific and more stringent than applicable OSHA regulations. Compatibility with OSHA regulations is seldom an issue. (source)

OSHA 1910.5(c)(1) - What OSHA code applies in Los Angelos?

If a particular standard is specifically applicable to a condition, practice, means, method, operation, or process, it shall prevail over any different general standard which might otherwise be applicable to the same scenario. (source)

CACLABC 1015.2 - Where is guardrail required in Los Angelos?

Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps, and landings that are located more that 30 inches measured vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. (source)

Cal-OSHA 3210 - At what height do I need fall protection or guardrail in Los Angelos?

Guardrails are required on any elevated surface above 30 inches. (source)

Cal-OSHA 1620 - What can a guardrail be made out of in Los Angelos?

Railings shall be constructed of wood or in an equally substantial manner from other materials, and must comply with all other guardrail standards. (source)

CACLABC 1015.3 - How tall does rooftop guardrail need to be in Los Angelos?

Guards can not be less than 42 inches high. (source)

Cal-OSHA 3209(c) - How far apart can guardrail posts be in Los Angelos?

Guardrail posts may not be spaced more than eight feet apart. (source)

Cal-OSHA 1620 - Do I need a mid-rail in Los Angelos?

A mid-rail shall be halfway between the top rail and the floor, platform, runway or ramp when there is no wall or parapet wall at least 21 inches high. (source)

Cal-OSHA 1632 - When do I need a toeboard in Los Angelos?

Where there is danger of items falling from an elevated surface, covers or guardrail with toeboards must be provided. (source)

CACLABC 1607.8.1 - What are the load requirements for rooftop railing in Los Angelos?

All railings must be able to withstand a concentrated load of 200 pounds and a linear load of 50 pounds per linear foot. (source)

Cal-OSHA 3209 - Can I use a non-penetrating guardrail in Los Angelos?

Yes, as long as it complies with all other guardrail standards. (source)

CACLABC 1014 - Can guardrail serve as handrail in Los Angelos?

Guardrails and handrails serve two different purposes and have different requirements. A handrail may be attached to a guardrail, but they are not one in the same. (source)

CACLABC 1015.7 - If my rooftop is lower than 22 feet but I have a roof hatch close to the edge, do I need rooftop railing in Lincoln?

If you have a roof hatch located within 10 feet of the roof edge, the roof access or roof edge must be protected by guardrail. (source)

CACLABC 1015.2 - If my rooftop is lower than 22 feet but I have mechanical equipment close to the edge, do I need rooftop railing in Lincoln?

Guards must be located along open-sided walking surfaces, including equipment platforms, that are located more that 30 inches measured vertically to the floor or grade below any point within 36 inches horizontally to the edge of the open side. (source)

Cal-OSHA 1632 - When is protection required when falling through a hole in Los Angelos?

Every roof opening must be guarded by either railings and toeboards or by covers. The covers must be able to withstand a minimum of 400 pounds. (source)

Popular Fall Protection Products in Los Angeles

Have any Questions about Fall Protection?

We pride ourselves on not being "just another company trying to sell you something". We take safety seriously and we want to partner with you to make sure you receive the right fall protection solution that meets compliance requirements, protects your workers while they work at height, and reduces liability for your company.

Michael Hannah at desk
Michael Hannah
Fall Protection Specialist
Or call a specialist at:
1.866.527.2275

Contact Information

Michael Hannah
Fall Protection Specialist

Shopping Cart

Show Pricing

Option available in footer.